Tekniska data
Analog inputs | |||
---|---|---|---|
Quantity | 16 | ||
Sensors | Thermocouples, RTD, mV, mA | ||
Total sampling rate | 60 Hz | ||
Voltage and current measurement range | 156 mV .. 10 V, ± 156 mV .. ± 10 V / 0 .. 20 mA, 4 .. 20 mA, ± 20 mA | ||
Galvanic isolation to system | 750 VDC | ||
Galvanic isolation channel to channel | 650 V | ||
Resolution/Type ADC | 24 bit Sigma-Delta | ||
Measurement accuracy | V / mA: 0.01 % from upper range value (URV)
Pt100(0): 0.1 K Thermocouples: 0.1 % URV after compensation |
||
Data storage | |||
Internal | 0.5 .. 15.5 GB (approx. 30 million mesurement values per GB) | ||
Interfaces | |||
Physical equipment COM 1 / COM 2 |
RS485, 9-pole sub-D socket, IEC 61158-2 | ||
Physical equipment COM 3 / COM 4 |
RS232, 9-pole sub-D socket (COM 3), 9-pole sub-D plug (COM 4) | ||
Protocols COM 1 .. COM 4 | Modbus RTU master / slave, customer-specific protocols, ASCII, SCPI | ||
TCP/IP | RJ45 (8-pole STP-socket), 100Base-TX; Protocols: TCP/IP, HTTP, SMTP, NTP, Modbus TCP and OPC UA client / server | ||
USB | USB 1.1 for data memory read out | ||
CAN | 9-pole sub-D socket, Protocols: CAN RAW; baud rates: 50 k .. 1 MBaud | ||
General technical information | |||
Dimension / weight | W 200 x H 73 x D122 mm / 1 kg | ||
Fixing | Rail mounting DIN EN 60715 or screw fixing | ||
Signal connections | Detachable screw terminals, 33 terminals in 2 rows, lead protection, connecting cabling max. 2.5 mm² | ||
Temperature range | -20 .. 50 °C | ||
Humidity | max. 90 % relative humidity, non-condensing | ||
Power supply | 12 .. 36 VDC / 12 .. 28 VAC eff. / ± 10 % | ||
Power input | < 10 Watt |